Here is an example Real Time Control (RTC) rule for the opening and closing of  an orifice in SWMM5.
RULE Orifice1
IF SIMULATION  CLOCKTIME >=  01:00:00
AND SIMULATION CLOCKTIME <=  2:00:00
THEN ORIFICE OR1@82309b-15009b SETTING = 1
ELSE ORIFICE OR1@82309b-15009b SETTING = 0
PRIORITY 1
; Opens up the orifice at hour 1 of the simulation