InfoSWMM and H2oMAP SWMM Map of the Maximum Surcharge Depth Over Highest Pipe Crown

Note:  You can copy and paste information from the Junction Output Summary to a newly created Junction Information DB Column so that you can use Map Display to visually see the newly saved output variable.

 

Step 1:  Run the model and then go to the Junction Summary in Report Manager and select all of the nodes in your model.

 

 

Step 2:  Copy the Maximum Surcharge Height over Highest Pipe Crown Column

 

 

 

Step 3:  Make and Insert a New Editable Field in the Junction Information Table by Pasting the information you just copied from the Junction Summary  Output Column.

 

 

Step 4:  Use the Map Display Command and use Existing DB as the Source and the newly created variable Junction_Surcharge_Depth

 

 

Step 5:  Use the Option Show Label Properties and adjust the Font to show the maximum surcharge depth.

 

 

 

via Blogger http://www.swmm5.net/2013/07/infoswmm-and-h2omap-swmm-map-of-maximum.html

about author

Storm/Sewer Modeler with a 45 yr association with EPASWMM. Now at Autodesk supporting InfoWorks ICM_SWMM Founder http://robertdickinson.org, Chair/TAC at http://CIMM.ORG

robert.dickinson@gmail.com

Storm/Sewer Modeler with a 45 yr association with EPASWMM. Now at Autodesk supporting InfoWorks ICM_SWMM