Importing Data from InfoSewer to InfoSWMM

Importing Data from InfoSewer to InfoSWMM

The direct import of InfoSewer to InfoSWMM (Figure 1) is both direct and robust, but you must be aware of Run Manager changes to optimize the InfoSWMM model:

  1. Ensure that the Flow Units in InfoSWMM Run Manager match the default flow units in InfoSewer
Read the rest

How to Model H2S in ICM

How to Model H2S in ICM

Hydrogen Sulphide Input Data and Equations w/ Sample Model

Figure ICMT Contents

Figure ICM Network - BOD is loaded at LoadNode

Introduction:

How to simulate H2S in InfoWorks ICM – the attached ICMT file is called H2S_ICM for ICM 2021.1

The presence
Read the rest

InfoSWMM Risk Assessment Manager and How to Create Flood Damage Rasters

1. Create flood damage extent

The InfoSWMM Risk Assessment Manager is laid out according to the duties required for risk assessment. Four options are found in the drop-down menu of the risk assessment. Each of these instructions launches a new dialog box where users can submit further information. The following … Read the rest

How to use GIS Gateway in InfoSWMM to Create both Data and Model Results Shapefiles

GIS Gateway - Create Shapefile

From the GIS Gateway, the Build Shapefile tool lets you create a new ESRI® Shapefile from InfoSWMM data. Every attribute can be loaded into the new Shapefile attribute table by using the data associated with each attribute type. The application of the tool can be Read the rest

Junction DWF in SWMM5, InfoSWMM and ICM SWMM Networks

Junction Dry Weather Flow (DWF)

The Junction Dry Weather Flow (DWF) data table stores information regarding the dry weather load (e.g., sanitary loads) entering the collection system at the junction node. Refer to the section on the inflow editor for more information on these input data. The following table shows Read the rest

InfoSWMM Designer Tutorial

Introduction to Example One

This project modified in this tutorial illustrates how Designer calculates sewer conduit size, storage volume, and pump size to meet specified design criteria at the minimum cost.

The model schematic is shown on the next page. The model contains two wastewater treatment plants (outfall110 and outfall94), … Read the rest

Features of the 1D St Venant solution for SWMM5, InfoSWMM, and ICM SWMM Networks

Question: How does SWMM5 solve the 1D St Venant Equation in its conceptual Link/Node Network?

Answer: See these graphs of the solved for variables in the solution.


1/ There is also an ArcEngine version of InfoSWMM call InfoSWMM SA. I will SA to show some hidden features of the 1D Read the rest

InfoSWMM 2D Exercises

Chapter 12 Exercises

InfoSWMM 2D

The exercises in this chapter will give you practice in exploring some of the additional reporting features of InfoSWMM 2D.

Exercise 12A Initialize the InfoSWMM 2D Model

In this exercise, you will create a 2D Model in InfoSWMM.

1. Open the project located at C:\Training\InfoSWMM\Ch12\Ch12Start.mxdRead the rest