Detention Pond Infiltration and Evaporation Losses in SWMM 5

Subject:  Detention Pond Infiltration and Evaporation Losses 
You can also add a storage pond infiltration and surface evaporation losses to the pond.  The surface evaporation is added to theinfiltration (computed from the green ampt parameters); a storage volume summary listing the average and maximum volume and the percent loss from the combined infiltration and evaporation from the ponds.  The pond infiltration loss during a time step is basd on the areal weighed average depth, the Green Ampt infiltration and the Area of the pond.

via Blogger http://www.swmm5.net/2013/08/detention-pond-infiltration-and.html