How to Use the Map Display for the Maximum Adjusted d/D or Maximum q/Q in an EPS InfoSewer Simulation
You can do a Map Display of the adjusted d/D values (Figure 1) from the Gravity Main Range Report (Figure 2) to show those pipes that are full thematically. For example, the links in red in Figure 1 show the effect of the pump blockage and the links in green are those NOT full due to the pump blockage. You will need to copy the adjusted d/D or the maximum q/Q values from the Range report to the Link Information Table to have some values to Map (Figure 3 and 4). The maximum adjusted d/D or the Maximum q/Q can be mapped using the new link information (Figure 5).
Figure 1 Map Display of the Maximum Adjusted d/D from the Gravity Range Report.
Figure 2. Maximum Adjusted d/D or Maximum q/Q can be copied from the EPS Range Gravity Main Report.
Figure 3. Create a new variable In the Link Information Table.
Figure 4. New variables for the Map Display from the Range Report in the Pipe Information Tables for Each Link.
Figure 5. Link Information new Parameters of Variables can be used to Display the maximum d/D or q/Q during the EPS simulation.
via Blogger http://www.swmm5.net/2013/08/how-to-use-map-display-for-maximum.html
You may also like
-
How to Setup RDII in InfoSewer Pro (Storms)
-
How to ReMake an IEDB Folder for InfoSewer
-
How to Make an Internal Outfall into an External Outfall when you have more than one link connected to an Outfall in SWMM5 or InfoSWMM
-
New Domain Nodes and Links in InfoSewer
-
How to Use Population for DWF in SWMM5 and InfoSWMM