Pump Summary Report for better Model Output Analysis in InfoSWMM and InfoSWMM SA
The Pump Summary report table presents a summary of some pump result variables that could assist the modeler to easily analyze the drainage system.
The following variables are displayed on the pump summary report for all or selected pumps depending on the report scope ( i.e., show complete report/graph, select elements, use Domain, use selection set, use provided element ID(s)) chosen on the Output Report and Graph dialog box. The summary is provided for the entire reporting length specified in the simulation options - dates tab.
Description of buttons and fields in the report.
BUTTON | NAME | DESCRIPTION |
![]() |
Refresh Report | |
![]() |
Print Report | |
![]() |
Format Report | |
![]() |
Format Column | |
![]() |
Change Font | |
![]() |
Copy | |
![]() |
Sort Ascending | |
![]() |
Sort Descending | |
![]() |
Filtering | |
![]() |
Find | |
![]() |
Frequency Graph | Click here to learn more. |
![]() |
Save Selection | |
![]() |
Compare Report | |
ID | Pump link identifier | |
Maximum Flow | Maximum flow delivered by the pump within the simulation duration | |
Maximum Flow Day -Time Count | Number of days (i.e., elapsed day) since the simulation start time to the instant when maximum flow at the pump, and number of hours, counted from the day when maximum flow occurred at the pump, to the time of occurrence of maximum flow at the pump | |
Average Flow | Average flow through the pump | |
Total Volume | Total volume delivered by the pump within the simulation duration | |
Total Surcharge Time | Total time the pump was on | |
Power Usage | Power used by the pump during the simulation duration | |
Percent Utilized (%) | Time the pump was on (flow greater than zero) | |
Time Off Curve (%) | Time the pump flow was off the Flow-Head curve | |
Instability Index | ||
Startup Up Count | Number of times the pump turns on during the simulation | |
Time Off Low Curve | The percent of time the head across the pump was less than the lowest head in the pump curve table | |
Time Off High Curve | The percent of time the head across the pump was higher than the highest head in the pump curve table |