August 2013

InfoSWMM, Inside SWMM5, SWMM5, Venant

The Link Time Step in SWMM 5, InfoSWMM and H2OMap SWMM

Introduction:  This set of blogs uses the 1000 year rainfall/runoff/hydraulics model that you can download at http://swmm2000.com/forum/topics/1000-year-simulation-with-rainfall-in-swmm-5 to show the inner workings of SWMM 5 and by extension InfoSWMM and H2oMap SWMM using a QA/QC version of SWMM 5 with extended graphics.   I always hope that seeing the inner workings
Read the rest
ARC GIS, InfoSWMM, SWMM5

InfoSWMM Error Messages and Arc Map Invalid Characters

InfoSWMM Error Messages and Arc Map Invalid Characters
A few other invalid characters are shown here in addition to the space character.  The Arc Map Link is http://www.esri.com/news/arcuser/1010/joinvalidate.htmlif you want more information.
000354 : The name contains invalid characters
Description
Any database may have naming restrictions for
Read the rest
History, ICM, InfoSWMM, SWMM5

UK Environment Agency Study Confirms Leading Capabilities of InfoWorks ICM

Innovyze Press Release
 Insider BlogLinkedInTwitterYouTubeYouTube
UK Environment Agency Study Confirms Leading Capabilities of InfoWorks ICM
Innovyze Smart Integrated Catchment Solution Excels in Examination of Two-Dimensional Modeling Solutions
Broomfield, Colorado, USA, August 20, 2013 — Innovyze, a leading global innovator of business analytics software
Read the rest
#INFOSEWER, #INFOSWMM, Force Mains, InfoSWMM, SWMM5

Vacuum Sewers

Vacuum Sewers

Compiled by:
Beat Stauffer (seecon international gmbh)

Source:  http://www.sswm.info/category/implementation-tools/wastewater-collection/hardware/sewers/vacuum-sewers

Executive Summary

Vacuum sewerage systems consist of a vacuum station, where the vacuum is generated, the vacuum pipeline system, collection chambers with collection tanks and interface valve units. In contrast to conventional gravity sewerage systems with intermediate pumping
Read the rest
InfoSWMM, SWMM5

How to Set a Flap Gate in InfoSWMM

Note:  How to Set a Flap Gate in InfoSWMM

 You can set a flap gate in InfoSWMM either by using the attribute browser and changing the Flap Gate Installed to Yes or No or by using the DB Editor and changing the Flag for Flap Gate Installed to Yes by Read the rest

InfoSWMM, SWMM5

SWMM 5 Arrow Direction Question

Subject:   SWMM 5 Arrow Direction Question

 

question often asked is what happens to the flow in a SWMM 5 link if the downstream and upstream node names are entered in reverse.    The flow will be exactly the same as if the nodes were entered in the right order but Read the rest

Translate »